SGI UV 2000 Guide de l'utilisateur Page 1

Naviguer en ligne ou télécharger Guide de l'utilisateur pour Serveurs SGI UV 2000. SGI UV 2000 User guide Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 110
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs

Résumé du contenu

Page 1 - UV 2000 System User Guide

SGI® UV 2000 System User Guide Document Number 007-5832-001

Page 2

x 007-5832-001List of FiguresFigure 7-1 UV Compute Blade Status LED Locations Example. . . . . . . 70Figure 7-2 Full Support S

Page 3 - Record of Revision

82 007-5832-001A: Technical Specifications and PinoutsSerial PortsThe IRU and the optional router modules have 9-pin serial interface connectors. Thes

Page 4

I/O Port Specifications007-5832-001 83Table A-7 shows pinout assignments for the 9-pin male DB-9 connector.Table A-7 Serial Port Pinout Pin Assignment

Page 5 - Contents

84 007-5832-001A: Technical Specifications and PinoutsUSB Type A ConnectorFigure A-4 shows the USB type A connector provided on the baseIO riser blade

Page 6

007-5832-001 85Appendix BB. Safety Information and Regulatory SpecificationsThis appendix provides safety information and regulatory specifications fo

Page 7 - 007-5832-001 vii

86 007-5832-001B: Safety Information and Regulatory Specifications9. Do not attempt to service this product yourself except as noted in this guide. Op

Page 8

Regulatory Specifications007-5832-001 87Regulatory SpecificationsThe following topics are covered in this section:• “CMN Number” on page 87• “CE Notic

Page 9 - List of Figures

88 007-5832-001B: Safety Information and Regulatory SpecificationsElectromagnetic EmissionsThis section provides the contents of electromagnetic emiss

Page 10

Regulatory Specifications007-5832-001 89Industry Canada Notice (Canada Only)This Class A digital apparatus meets all requirements of the Canadian Inte

Page 11 - List of Tables

90 007-5832-001B: Safety Information and Regulatory SpecificationsShielded CablesThis SGI system is FCC-compliant under test conditions that include t

Page 12

Regulatory Specifications007-5832-001 91Laser Compliance StatementsThe DVD-ROM drive in this computer is a Class 1 laser product. The DVD-ROM drive’s

Page 13 - About This Guide

007-5832-001 xiList of TablesTable 4-1 Tall Rack Technical Specifications . . . . . . . . . . . 52Table 5-1

Page 14 - Chapter Descriptions

92 007-5832-001B: Safety Information and Regulatory SpecificationsLithium Battery StatementWarning: There is danger of explosion if a lithium battery

Page 16

007-5832-001 xiiiAbout This GuideThis guide provides an overview of the architecture, general operation and descriptions of the major components that

Page 17 - Conventions

xiv 007-5832-001About This GuideChapter DescriptionsThe following topics are covered in this guide:• Chapter 1, “Operation Procedures,” provides instr

Page 18 - Reader Comments

Related Publications007-5832-001 xvRelated PublicationsThe following SGI documents are relevant to the UV 2000 series system:• SGI UV CMC Software Use

Page 19 - 1. Operation Procedures

xvi 007-5832-001About This Guide• SGI UV Systems Linux Configuration and Operations Guide(P/N 007-5629-00x)This guide is a reference document for peop

Page 20 - Power Connections Overview

Conventions007-5832-001 xviiFor additional information about displaying man pages using the man command, see man(1). In addition, the apropos command

Page 21 - 1 (on) position

xviii 007-5832-001About This GuideProduct SupportSGI provides a comprehensive product support and maintenance program for its products, as follows:• I

Page 22 - 1: Operation Procedures

007-5832-001 1Chapter 11. Operation ProceduresThis chapter explains the basics of how to operate your new system in the following sections:• “Precauti

Page 23 - 007-5832-001 5

COPYRIGHT© 2012 SGI. All rights reserved; provided portions may be copyright in third parties, as indicated elsewhere herein. No permission is granted

Page 24 - 6 007-5832-001

2 007-5832-0011: Operation ProceduresSafety PrecautionsWarning: Before operating or servicing any part of this product, read the “Safety Information”

Page 25 - System Connections Overview

Power Connections Overview007-5832-001 3long as there is power coming into the unit. Turn off the PDU breaker switch on each of the PDUs that supply v

Page 26 - System Controller Access

4 007-5832-0011: Operation ProceduresFigure 1-2 Single-Phase 2-Outlet PDU Example Figure 1-3 on page 5 shows an example of an eight-plug single-phase

Page 27 - 007-5832-001 9

Power Connections Overview007-5832-001 5Figure 1-3 Single-Phase 8-Outlet PDU Powerdistributionunit (PDU)Powersource

Page 28 - Using a Static IP Address

6 007-5832-0011: Operation ProceduresFigure 1-4 shows examples of the three-phase PDUs that can be used in the SGI UV 2000 system. These PDUs are used

Page 29

System Connections Overview007-5832-001 7System Connections OverviewYou can monitor and interact with your SGI UV 2000 server from the following sourc

Page 30 - System Control Overview

8 007-5832-0011: Operation ProceduresA micro-USB serial connection can be used to communicate directly with the CMC. This connection is typically used

Page 31 - 007-5832-001 13

System Connections Overview007-5832-001 9Serial Console Hardware RequirementsThe console type and how these console types are connected to the SGI UV

Page 32 - The Command Line Interface

10 007-5832-0011: Operation ProceduresNote: Both options require the use of the CMC's serial port, refer to Figure 1-6 on page 8.For DHCP, you m

Page 33 - Command Options for Power On

System Connections Overview007-5832-001 11BOOTPROTO=staticIPADDR=<IP address to use>NETMASK=<netmask>GATEWAY=<network gateway IP addres

Page 34 - 16 007-5832-001

007-5832-001 iiiRecord of RevisionVersion Description001 June 2012First Release

Page 35 - Booting Directly From a CMC

12 007-5832-0011: Operation ProceduresSystem Control OverviewAll SGI UV 2000 system individual rack units (IRUs) use an embedded chassis management co

Page 36 - 18 007-5832-001

System Control Overview007-5832-001 13Communicating with the System The two primary ways to communicate with and administer the SGI UV 2000 system are

Page 37 - \efi\SuSE\elilo

14 007-5832-0011: Operation Procedures5. On the command line, enter mgrclient and press Enter. The SGI Management Center Login dialog box is displayed

Page 38 - Power off a UV System

System Control Overview007-5832-001 15about its internal blades, and also (if other IRUs are attached via NUMAlink to the IRU) information about those

Page 39

16 007-5832-0011: Operation ProceduresThe system will take time to fully power up (depending on size and options).Specific CLI Commands Used With the

Page 40 - 22 007-5832-001

System Control Overview007-5832-001 17Note: The command line interface for the CMC is virtually the same as that for the SMN, with the exception that

Page 41 - Optional Components

18 007-5832-0011: Operation ProceduresThe system will take time to fully power up (depending on size and options). Larger systems take longer to fully

Page 42 - 24 007-5832-001

System Control Overview007-5832-001 19Monitoring Power OnOpen a separate window on your PC or workstation and establish another connection to the SMN

Page 43 - 2. System Control

20 007-5832-0011: Operation ProceduresPower off a UV SystemTo power down the UV system, use the power off command, as follows:CMC:r1i1c> power off=

Page 44 - 2: System Control

System Control Overview007-5832-001 21usage: power [-v10ud] [status] [system-SSN]...show power status-v, --verbose verbose output-1, --on

Page 46 - 28 007-5832-001

22 007-5832-0011: Operation ProceduresUsing Embedded Support Partner (ESP) Embedded Support Partner (ESP) automatically detects system conditions that

Page 47 - System Controller Interaction

Optional Components007-5832-001 23Optional ComponentsBesides adding a network-connected system console or basic VGA monitor, you can add or replace th

Page 48 - IRU Controllers

24 007-5832-0011: Operation ProceduresFigure 1-7 PCIe Option Blade Example with Full-Height and Low-Profile SlotsFigure 1-8 PCIe Option Blade Example

Page 49 - 007-5832-001 31

007-5832-001 25Chapter 22. System Control This chapter describes the general interaction and functions of the overall SGI UV 2000 system control. Syst

Page 50 - 32 007-5832-001

26 007-5832-0012: System ControlSystem Management Node (SMN) OverviewAn Ethernet connection directly from the SMN (Figure 2-1 on page 27) to a local p

Page 51 - 3. System Overview

Levels of System Control007-5832-001 27Figure 2-1 System Management Node Front and Rear PanelsCMC OverviewThe CMC system for the SGI UV 2000 servers m

Page 52 - SGI UV 2000

28 007-5832-0012: System Controlblade installed. The CMC provides data collected from the compute nodes within the IRU to the system management node u

Page 53 - System Models

System Controller Interaction007-5832-001 29BMC OverviewEach compute blade in an IRU has a baseboard management controller (BMC). The BMC is a built-i

Page 54 - 1U (I/O) Expansion Slot

30 007-5832-0012: System ControlIRU ControllersAll IRUs have a chassis management controller (CMC) board installed. The following subsection describes

Page 55 - System Architecture

IRU Controllers007-5832-001 31Figure 2-3 Optional 1U Rackmount ConsoleFlat Panel Rackmount Console Option FeaturesThe 1U flat panel console option has

Page 56 - Backplane

007-5832-001 vContentsList of Figures . . . . . . . . . . . . . . . . . . .

Page 57 - System Features

32 007-5832-0012: System Control4. Power LED - Illuminates blue when the unit is receiving power.The 1U console attaches to the system management node

Page 58 - BOTTOM NODE PCA W/BMC

007-5832-001 33Chapter 33. System OverviewThis chapter provides an overview of the physical and architectural aspects of your SGI UV 2000 series syste

Page 59 - Distributed Shared I/O

34 007-5832-0013: System OverviewFigure 3-1 SGI UV 2000 Single-Rack System ExampleSGI UV 2000

Page 60 - 3: System Overview

System Models007-5832-001 35System ModelsThe basic enclosure within the SGI UV 2000 system is the 10U high “individual rack unit” (IRU). The IRU encl

Page 61 - 007-5832-001 43

36 007-5832-0013: System OverviewFigure 3-2 SGI UV 2000 IRU and Rack Individual Rack Unit (IRU)(System Management Node)1U (I/O) Expansion SlotUV RackI

Page 62 - System Components

System Architecture007-5832-001 37System ArchitectureThe SGI UV 2000 computer system is based on a distributed shared memory (DSM) architecture. The

Page 63 - 007-5832-001 45

38 007-5832-0013: System OverviewFigure 3-3 Functional Block Diagram of the Individual Rack Unit NI2-3NI2-3NI0-3NI0-3NI2-3NI2-3NI0-3NI0-3NI2-3NI2-3NI0

Page 64 - Optional System Components

System Features007-5832-001 39System FeaturesThe main features of the SGI UV 2000 series server systems are discussed in the following sections:• “Mo

Page 65 - 4. Rack Information

40 007-5832-0013: System OverviewFigure 3-4 Blade Node Block Diagram Chan-0Chan-1Chan-2Chan-3QPILocal Bus 0 &1BNI Bus 0 & 1NL612ChannelsBACKPL

Page 66 - SGI UV 2000 Series Rack (42U)

System Features007-5832-001 41Distributed Shared I/OLike DSM, I/O devices are distributed among the blade nodes within the IRUs. Each BaseIO riser ca

Page 67

vi 007-5832-001ContentsSystem Control Overview . . . . . . . . . . . . . . . . .

Page 68

42 007-5832-0013: System OverviewWhen a processor modifies a block of data, the processors that have the same block of data in their caches must be no

Page 69

System Features007-5832-001 43– Each blade/node installed has status LEDs that indicate the blade’s operational condition; LEDs are readable at the f

Page 70 - Characteristic Specification

44 007-5832-0013: System OverviewSystem ComponentsThe SGI UV 2000 series system features the following major components:• 42U rack. This is a custom r

Page 71 - Overview

System Components007-5832-001 45Figure 3-5 SGI UV 2000 IRU System Components Example Computeblade 3Computeblade 2Computeblade 1Computeblade 0PS0 PS2P

Page 72 - 54 007-5832-001

46 007-5832-0013: System OverviewFigure 3-6 BaseIO Riser Enabled Blade Front Panel ExampleBay (Unit) NumberingBays in the racks are numbered using sta

Page 73 - 007-5832-001 55

007-5832-001 47Chapter 44. Rack InformationThis chapter describes the physical characteristics of the tall (42U) SGI UV 2000 racks in the following se

Page 74 - ORC chassis

48 007-5832-0014: Rack InformationSGI UV 2000 Series Rack (42U)The tall rack (shown in Figure 4-1 on page 49) has the following features and component

Page 75 - 6. Add or Replace Procedures

SGI UV 2000 Series Rack (42U)007-5832-001 49Each three-phase power distribution unit has 9 outlet connections. Figure 4-1 SGI UV 2000 Series Rack Exam

Page 76 - 6: Add or Replace Procedures

50 007-5832-0014: Rack InformationFigure 4-2 Front Lock on Tall (42U) Rack SGI UV 2000

Page 77 - 007-5832-001 59

SGI UV 2000 Series Rack (42U)007-5832-001 51Figure 4-3 Optional Water-Chilled Cooling Units on Rear of SGI 42U RackSGI UV 2000

Page 78 - Support levels in

Contents007-5832-001 viiSystem Features . . . . . . . . . . . . . . . . . . .

Page 79

52 007-5832-0014: Rack InformationSGI UV 2000 System Rack Technical SpecificationsTable 4-1 lists the technical specifications of the SGI UV 2000 seri

Page 80 - 62 007-5832-001

007-5832-001 53Chapter 55. Optional Octal Router Chassis InformationThis chapter describes the optional NUMAlink router technology available in SGI UV

Page 81 - 007-5832-001 63

54 007-5832-0015: Optional Octal Router Chassis InformationSGI UV 2000 Series NUMAlink Octal Router ChassisThe NUMAlink 6 ORC router is a 7U-high full

Page 82 - 64 007-5832-001

SGI UV 2000 Series NUMAlink Octal Router Chassis007-5832-001 55Figure 5-2 SGI UV 2000 Optional ORC Chassis Example (Front View)Note: The NUMAlink uni

Page 83 - 007-5832-001 65

56 007-5832-0015: Optional Octal Router Chassis InformationSGI UV 2000 External NUMAlink System Technical SpecificationsTable 5-1 lists the basic tech

Page 84

007-5832-001 57Chapter 66. Add or Replace ProceduresThis chapter provides information about installing and removing PCIe cards and system disk drives

Page 85 - Chapter 7

58 007-5832-0016: Add or Replace ProceduresPreparing the System for Maintenance or UpgradeTo prepare the system for maintenance, follow these steps:1.

Page 86 - Troubleshooting Chart

Overview of PCI Express (PCIe) Operation007-5832-001 59Overview of PCI Express (PCIe) OperationThis section provides a brief overview of the PCI Expre

Page 87 - LED Status Indicators

60 007-5832-0016: Add or Replace ProceduresSGI UV 2000 PCIe technology is available up to a x16 connector (64 wires) or “by 16” in PCI Express card sl

Page 88 - Compute/Memory Blade LEDs

Adding or Replacing PCIe Cards in the Expansion Enclosure007-5832-001 61Installing Cards in the 1U PCIe Expansion ChassisThe PCIe expansion chassis fu

Page 89 - SGI Electronic Support

viii 007-5832-001ContentsLED Status Indicators . . . . . . . . . . . . . . . . .

Page 90 - 72 007-5832-001

62 007-5832-0016: Add or Replace Procedures6. Fit the PCIe card into the slot connector with the connector(s) extending out the front of the bracket,

Page 91 - 007-5832-001 73

Adding or Replacing PCIe Cards in the Expansion Enclosure007-5832-001 63Figure 6-3 Card Slot Locations

Page 92

64 007-5832-0016: Add or Replace ProceduresRemoving and Replacing an IRU Enclosure Power SupplyTo remove and replace power supplies in an SGI UV 2000

Page 93 - System-level Specifications

Adding or Replacing PCIe Cards in the Expansion Enclosure007-5832-001 653. Press the retention latch of the power supply toward the power connector to

Page 95 - Environmental Specifications

007-5832-001 67Chapter 77. Troubleshooting and DiagnosticsThis chapter provides the following sections to help you troubleshoot your system:• “Trouble

Page 96 - Power Specifications

68 007-5832-0017: Troubleshooting and DiagnosticsTroubleshooting ChartTable 7-1 lists recommended actions for problems that can occur. To solve proble

Page 97 - I/O Port Specifications

LED Status Indicators007-5832-001 69LED Status IndicatorsThere are a number of LEDs on the front of the IRUs that can help you detect, identify and po

Page 98 - Pin Number Function

70 007-5832-0017: Troubleshooting and DiagnosticsCompute/Memory Blade LEDsEach compute/memory blade installed in an IRU has a total of seven LED indic

Page 99 - Ethernet Port

SGI Electronic Support007-5832-001 71SGI Electronic Support SGI Electronic Support provides system support and problem-solving services that function

Page 100 - Serial Ports

007-5832-001 ixList of FiguresFigure 1-1 IRU Power Supply Cable Location Example . . . . . . . . 3Figure 1-2 Sing

Page 101 - Pin Assignment Description

72 007-5832-0017: Troubleshooting and DiagnosticsThe sequence of events can be described as follows:1. Embedded Support Partner (ESP) software monitor

Page 102 - USB Type A Connector

SGI Electronic Support007-5832-001 73The following three components compose the integrated SGI Electronic Support system:SGI Embedded Support Partner

Page 104 - 86 007-5832-001

007-5832-001 75Appendix AA. Technical Specifications and PinoutsThis appendix contains technical specification information about your system, as follo

Page 105 - Regulatory Specifications

76 007-5832-001A: Technical Specifications and PinoutsPhysical SpecificationsTable A-2 shows the physical specifications of the SGI UV 2000 system.Not

Page 106 - Electromagnetic Emissions

Environmental Specifications007-5832-001 77Environmental SpecificationsTable A-3 lists the environmental specifications of the system.Table A-3 Enviro

Page 107 - Equipment Regulations

78 007-5832-001A: Technical Specifications and PinoutsPower SpecificationsTable A-4 shows the power specifications for the system.Table A-4 Power Spec

Page 108 - Electrostatic Discharge

I/O Port Specifications007-5832-001 79I/O Port SpecificationsThis section contains specifications and port pinout information for the base I/O ports o

Page 109 - Laser Compliance Statements

80 007-5832-001A: Technical Specifications and PinoutsTable A-5 VGA Pin FunctionsPin Number Function1Red2 Green3Blue4N/C5Ground6Ground7Ground8Ground9G

Page 110 - Lithium Battery Statement

I/O Port Specifications007-5832-001 81Ethernet PortThe system auto-selects the Ethernet port speed and type (duplex vs. half-duplex) when the server i

Commentaires sur ces manuels